BCM5722 Programmer’s Guide
10/15/07
Broadcom Corporation
Page 435 Transceiver Registers Document 5722-PG101-R
EXPANSION REGISTER 00H: RECEIVE/TRANSMIT PACKET COUNTER
The following expansion registers are enabled by writing to “Expansion Register Access Register (PHY_ADDR = 0x1,
Reg_Addr = 17h)” on page 434 bits [11:0] = F00h, and read/write access is through register 15h.
Packet Counter (Copper Only)
When the Packet Counter Mode bit field = 1, in the “Auxiliary Control Register (PHY_Addr = 0x1, Reg_Addr = 18h, Shadow
= 111, Misc Control)” on page 449, the number of receive packets is counted.
When the Packet Counter Mode bit field = 0, in the “Auxiliary Control Register (PHY_Addr = 0x1, Reg_Addr = 18h, Shadow
= 111, Misc Control)” on page 449, the number of transmit packets is counted. This counter is clear on read and freezes at
FFFFh.
EXPANSION REGISTER 01H: EXPANSION INTERRUPT STATUS
The following expansion registers are enabled by writing to “Expansion Register Access Register (PHY_ADDR = 0x1,
Reg_Addr = 17h)” on page 434 bits [11:0] = F01h, and read/write access is through register 15h.
Mode Select Change
This bit indicates that mode select change is detected.
SerDes Link Status Change
This bit indicates a SerDes link status change is detected.
Table 498: Expansion Register 00h: Receive/Transmit Packet Counter
Bit Field Description Init Access
15:0 Packet Counter
(Copper Only)
Returns the packet count 0000h R/W
SC
Table 499: Expansion Register 01h: Expansion Interrupt Status
Bit Field Description Init Access
15:8 Reserved Write as 00h, ignore on read. 00h RO
7 Mode Select Change
1 = Mode select change detected (clears on read).
0 = Mode select change not detected.
0RO
LH
6 SerDes Link Status Change
1 = SerDes link status change detected (clears on
read).
0 = Mode select change not detected.
0RO
LH
5:1 Expansion Interrupt Status
1 = Expansion Interrupt condition detected.
0 = Expansion Interrupt condition not detected.
00h RO
LH
0 Transmit CRC Error
(Copper Only)
1 = Transmit CRC error detected since last read.
0 = No Transmit CRC error detected since last read.
0RO
LH