EasyManua.ls Logo

Broadcom BCM5722 - Table 530: Misc 1000 BASE-X Status Register (Address 1 Ch, Shadow Value 11101)

Broadcom BCM5722
593 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BCM5722 Programmer’s Guide
10/15/07
Broadcom Corporation
Page 473 Transceiver Registers Document 5722-PG101-R
MISC 1000BASE-X STATUS (PHY_ADDR = 0X1, REG_ADDR = 1CH, SHADOW 11101B)
Write Enable
During a write to this register, setting Misc 1000BASE-X Status register bit 15 allows writing to bits [9:0] of this register. For
reading the values of bits [9:0], perform an MDIO write with bit 15 cleared and preferred shadow values in bits [14:10]. The
next MDIO read of register address 1Ch contains the preferred shadow register values in bits [9:0].
Shadow Register Selector
Register bits [14:10] must be set to 11101 to enable read/write to the Misc 1000BASE-X Status register.
TX FIFO Error
Bit 9 of Misc 1000BASE-X Status register indicates a transmit FIFO error since the last read.
RX FIFO Error
Bit 8 of Misc 1000BASE-X Status register indicates a receive FIFO error since the last read.
Table 530: Misc 1000BASE-X Status Register (Address 1Ch, Shadow Value 11101)
Bit Field Description Init Access
15 Write Enable 1 = Write bits [9:0].
0 = Read bits [9:0].
0R/W
14:10 Shadow Register Selector 11101 = Misc 1000BASE-X Status register. 11101 R/W
9 TX FIFO Error
1 = Transmit FIFO error since last read.
0 = No transmit FIFO error since last read.
0RO
LH
8 RX FIFO Error
1 = Receive FIFO error since last read.
0 = No receive FIFO error since last read.
0RO
LH
7:6 Reserved Write as 00, ignore when read. 00 RO
LH
5 False Carrier Detected
1 = False carrier detected since last read.
0 = No false carriers detected since last read.
0RO
LH
4 CRC Error Detected
1 = CRC Error detected since last read.
0 = No CRC error detected since last read or mode is
disabled via register 1Ch, shadow 11011, bit 0.
0RO
LH
3 Transmit Error Detected
1 = Transmit error code detected since last read
(rx_data_error state in PCS receive).
0 = No transmit error code detected since last read.
0RO
LH
2 Receive Error Detected
1 = Receive error since last read (early_end state in
PCS receive).
0 = No receive error since last read.
0RO
LH
1 Carrier Extend Error Detected
1 = Carrier extend error since last read (extend_err
state in PCS receive).
0 = No carrier extend error since last read.
0RO
LH
0 Early End Extension Detected
1 = Early end extension since last read (early_end_ext
state in PCS receive).
0 = No early end extension since last read.
0RO
LH