EasyManua.ls Logo

Broadcom BCM5722 - Table 504: Expansion Register 10 H: Cable Diagnostic Controls

Broadcom BCM5722
593 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmer’s Guide BCM5722
10/15/07
Broadcom Corporation
Document 5722-PG101-R Transceiver Registers Page 440
EXPANSION REGISTER 10H: CABLE DIAGNOSTIC CONTROLS
The following expansion registers are enabled by writing to “Expansion Register Access Register (PHY_ADDR = 0x1,
Reg_Addr = 17h)” on page 434 bits [11:0] = F10h, and read/write access is through register 15h.
Natural Link
Setting bit 2 = 1, skips the Open and Shorts check when in Cable Diagnostic Mode.
Cable Diag Begin
Setting bit 1 =1, begins the Cable Diagnostic Algorithm when in Cable Diagnostic Mode.
Cable Diag Mode
Setting bit 0 = 1, enables Cable Diagnostic Mode. See “Expansion Register 11h: Cable Diagnostic Results” on page 441,
“Expansion Register 12h: Cable Diagnostic Lengths Channels 1/2” on page 442, and “Expansion Register 13h: Cable
Diagnostic Lengths Channels 3/4” on page 443, for more details.
Table 504: Expansion Register 10h: Cable Diagnostic Controls
Bit Field Description Init Access
15:3 Reserved Write as 0000h, ignore on read. 0000h R/W
2 Natural Link
1 = Skips checking of open/short.
0 = Enables checking of open/short.
0R/W
1 Cable Diag Begin
1= Begins cable diagnostic algorithm.
0 = Cable diagnostic algorithm is not started.
0R/W
SC
0 Cable Diag Mode
1 = Cable diagnostic mode enabled.
0 = Cable diagnostic mode not enabled.
0R/W

Table of Contents