Programmer’s Guide BCM5722
10/15/07
Broadcom Corporation
Document 5722-PG101-R Transceiver Registers Page 474
False Carrier Detected
Bit 5 of Misc 1000BASE-X Status register indicates a false carrier detected since the last read.
CRC Error Detected
Bit 4 of Misc 1000BASE-X Status register indicates a CRC error detected since the last read.
Transmit Error Detected
Bit 3 of Misc 1000BASE-X Status register indicates a transmit error code detected since the last read.
Receive Error Detected
Bit 2 of Misc 1000BASE-X Status register indicates a receive error code detected since the last read.
Carrier Extend Error Detected
Bit 1 of Misc 1000BASE-X Status register indicates a carrier extend error since the last read.
Early End Extension Detected
Bit 0 of Misc 1000BASE-X Status register indicates an early end extension since the last read.