EasyManua.ls Logo

Broadcom BCM5722 - Page 535

Broadcom BCM5722
593 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmer’s Guide BCM5722
10/15/07
Broadcom Corporation
Document 5722-PG101-R Transceiver Registers Page 476
SerDes Auto Power Down mode
Bit 4 of the Autodetect Medium register enables the power down of SerDes when the filtered signal detect is inactive.
Power Down Inactive Interface
Bit 3 of the Autodetect Medium register enables the power down of SerDes when copper is selected, and power down of
copper when SerDes is selected.
Autodetect Media Default
Bit 2 of the Autodetect Medium register enables the selection of SerDes as default medium when no medium is active.
Clearing this bit sets copper as the default medium.
Autodetect Media Priority
Bit 1 of the Autodetect Medium register enables the selection of SerDes priority when both media are active. Clearing this
bit sets copper as the default medium selection.
Autodetect Media Enable
Bit 0 of the Autodetect Medium register enables the autodetect media function.