Resetting a Drive
From the Web User Interface: Service Library Reset Drives Reset
From the Operator Panel: Tools Service Drives Drive Tests
Reset Select Module(s) Select Drive(s)
Some hardware or firmware failures may require a drive be reset for recovery from
the failure.
Drives can be reset individually, by enclosure (module), by logical library (Web
User Interface only), or by entire library.
Shutting Down/Restarting the Library
Shut down the library for servicing. Restart the library after servicing and for
preparing it for use.
Shutting Down the Library
Servicing some components requires only that you take the library offline, while
servicing other components requires that you power OFF the entire library. For
details, see “Required Library State” on page 8-2. When library power is switched
OFF, the Picker assembly slowly falls to rest at the bottom of the library.
Shutting down a library shuts down the library's operating system and firmware.
When performing a shutdown, the library finishes all active commands received
from the host application and does not process any new commands. It takes all
logical libraries offline and lowers the robot to the “shipping” position on the floor
of the library. Always perform a shutdown before removing power from the
library.
Important: To completely remove all power before servicing or in an emergency,
push the front power button, toggle each power supply switch to the
OFF (O) position, and disconnect all power cords from their electrical
source.
1. Using the library's Operator Panel, ensure that no applications are accessing the
library. If a Progress Screen is open, wait until the operation completes.
2. Take the entire library (including all drives and logical libraries) offline.
v To take each logical library offline using the Operator Panel, select
Operations Logical Library Mode.
v To take each drive offline using the Operator Panel, select Operations
Change Drive Mode.
3. Shut down the library from the Operator Panel by selecting Operations
Shutdown. The System Shutdown window appears.
4. In the System Shutdown window, select Shutdown and click Apply.
5. In the System Shutdown Confirmation window, click Yes.
6. Press the power button located on the front of the control module.
7. Toggle each power supply switch to the OFF (O) position.
8. Disconnect the library's power cords from their electrical source.
Chapter 7. Service Procedures 7-39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing