v If the test fails, replace the fiber cable.
v If the test is successful, go to step 6.
6. Check the Fibre Channel cable connection at the server.
7. Using a device driver utility such as ntutil or tapeutil, verify that the drive is
properly configured and available at the server.
8. If the problem persists, the fault may be with the server's hardware or software.
Refer to your server's service manual.
9. When the problem is corrected (or determined to be a server problem), restore
all of the fiber cables to their correct position.
Fixing a Consistent Error with Multiple Drives on a Fibre
Channel Loop
Use the following procedure to determine if all of the drives on the Fibre Channel
have the problem:
1. Use a device driver utility (such as ntutil or tapeutil) to verify that the drive is
available and properly configured at the server.
2. Determine the type of Fibre Channel topology that you are using.
3. Using this guide or the service guides of associated switch, hub, or fiber
products, try to isolate which part of the Fibre Channel Storage Area Network
(SAN) is experiencing problems.
4. Perform one of the following:
v If the problem exists on a small number of drives, go to “Fixing a Consistent
Error with a Single Drive on a Fibre Channel Loop” on page D-55.
v If the problem exists with a large number of drives, perform the following
steps:
a. Disconnect all except one failing drive on the Fibre Channel.
b. Run the Fibre Channel wrap test to determine if a failure occurs on that
drive (see Function Code 6 in “Function Code 6: Run Host Interface Wrap
Test” on page D-32). If it does, perform the procedure in “Fixing a
Consistent Error with a Single Drive on a Fibre Channel Loop” on page
D-55.
c. Continue to connect one drive at a time to the Fibre Channel loop.
5. When the problem is corrected, restore all of the Fibre Channel cables to their
correct position.
Fixing a Consistent Error in a Point-to-Point Topology
1. Ensure that the tape drive is powered ON.
2. Verify that the tape drive's serial number is the same as the drive serial number
that the server program is using.
3. Ensure that the drive is connected to the host or switch. The drive must be able
to detect light and communicate with the server.
4. Run the Fibre Channel wrap test at the drive's Fibre Channel connector (see
Function Code 6 in “Function Code 6: Run Host Interface Wrap Test” on page
D-32).
v If the test fails, replace the tape drive.
v If the test is successful, go to step 5.
5. Run the Fibre Channel wrap test at the end of the fiber cable (see Function
Code 6 in “Function Code 6: Run Host Interface Wrap Test” on page D-32).
v If the test fails, replace the fiber cable.
D-56 TS3310 Tape Library Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing