3. Carefully return the library to an upright position.
4. Use the lifting sling to place the library module in the desktop location.
5. When you finish these desktop installation steps, store the installation sling in a
secure location for possible future use.
Manual Cartridge Removal from a Drive
The purpose of this section is to assist you in determining the condition of the
cartridge or the magnetic tape and to direct you to the procedure you must follow
to remove the cartridge.
Note: These procedure must be performed only by a trained IBM service provider.
SSRs should claim their time against service code 33 ECA 013 when
performing this procedure.
Note: If the cartridge in the drive is an INPUT tape containing ACTIVE or 'ONLY
COPY' data (i.e., there is no backup), and both eject commands issued at the
host and power-cycling the drive fail to eject the cartridge, make no further
attempts to unload this tape. Call Technical Support and open a PMR if one
isn't already open to initiate the process of sending the drive with the
loaded cartridge in for recovery.
v Before using this procedure, you must have exhausted all other means of
removing the tape cartridge from the drive. Use this procedure only if you
cannot remove the tape cartridge by using any other means.
a66mi103
Figure 8-133. Foot pad Locations
8-122 TS3310 Tape Library Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing

Related product manuals