EasyManuals Logo

IBM TS3310 User Manual

IBM TS3310
531 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
Resolution Before performing the following:
v “Removing a Drive Sled” on page 8-43.
v “Replacing a Drive Sled” on page 8-44.
refer to Chapter 1, “Start Service,” on page 1-1 for additional diagnostic
procedures.
v Perform “DR049: Resolve Drive TapeAlert 30, 31 - Drive Hardware Error”
on page 6-79.
v From the Operator Panel, select Tools Service Drives to run the drive
diagnostic. A blank, scratch cartridge is required for this test.
T050: Drive TapeAlert 31 - Hardware B
Description GUI Description: The tape drive detected an internal hardware problem.
Explanation: System determines that the drive has issued a TapeAlert 31
indicating a hardware error that requires a drive power cycle before the
drive might recover to a usable state.
Detection Scenario Tape drive issues a TapeAlert 31 which is recognized by the library during
the continuous four second polling cycle of drive status.
Root Causes Drive has determined that there is a problem per its internal algorithms.
Possible CRU Replacements Drive Sled
Resolution
v Perform “DR049: Resolve Drive TapeAlert 30, 31 - Drive Hardware Error”
on page 6-79.
v From the Operator Panel, select Tools Service Drives to run the drive
diagnostic. A blank, scratch cartridge is required for this test.
T051: Drive TapeAlert 32 - Interface
Description GUI Description: The tape drive reported an external data interface problem
Explanation: System determines that the drive has issued a TapeAlert 32
indicating a tape drive has detected a problem with the application client
interface.
Detection Scenarios Tape drive issues a TapeAlert 32 which is recognized by the library during
the continuous four second polling cycle of drive status.
Root Causes Drive has determined that there is a problem per its internal algorithms.
Possible CRU Replacements Drive Sled(only if all cables are OK and host communication to other drives
works)
Resolution
1. Perform “DR012: Resolve Drive Tape Alert 32 - Host Interface” on page
6-65.
2. Use the "Details" option in the RAS ticket to identify which tape drive
reported the RAS ticket.
3. Clear the RAS ticket.
4. Check the cabling from the back of the tape drive to the host and reseat
all the cables.
5. If RAS ticket persists, swap cables between drives to isolate a bad cable.
If this works and you can detect the drive, replace the bad cable.
6. If swapping cables did not fix the problem, then upgrade the tape drive
to the latest drive firmware.
6-24 TS3310 Tape Library Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3310 and is the answer not in the manual?

IBM TS3310 Specifications

General IconGeneral
Form FactorRack-mountable
Tape TechnologyLTO Ultrium
Product TypeTape Library
InterfaceFibre Channel
ExpansionExpandable with additional modules
Supported Tape TechnologyLTO Ultrium 5, LTO Ultrium 6
Weight120 lb (54.4 kg) (fully configured)
Power SupplyDual redundant power supplies
Operating Temperature41°F to 95°F (5°C to 35°C)
Non-operating Temperature-40°F to 140°F (-40°C to 60°C)
Humidity20% to 80% non-condensing