12.9.1 System data
Maximum configuration
Mobile telephones (MT) 64
SLMC8 boards 1
Base stations (BS) 8
SLMC8
Processor 80188
Program memory 512 Kbytes
U
P0/E
interface to base station:
Line protocol CorNet-T
Radio
4 B channels 32 kbit/s voice transmission each
max. four simultaneous calls
1 D channel 16 kbit/s signalling
Range
max. 1000 m line length depending on the type of cable (0.6 to 1.2 mm ). The
supply voltage at the BS must not fall below 35 V.
With a line length of 1000 m, the diameter of the a/b line must be uniform from
the MDFU/MDFU-E to the BS.
A reduction in the range may occur in some cases due to oxidised distribution
screw connections, differing wire diameters at specific points on the a/b line and
unsoldered line couplings.
The difference in signal delay times in base stations overlapping in the radio range must not
exceed 2 µs. For further information, please refer to page 12-51.
Connecting cables
The base stations are connected with two wires via the main distributor (MDFU/MDFU-E) of the
Hicom 150 E OfficePro system to the U
P0/E
interfaces.
Cable type Symmetrically stranded cable
(recommendation: JYSTY, 2 x 2 x 0.6 mm)
Hicom 150 E Office Rel.1.0 Service Manual - 12 Cordless Multicell Integration CMI
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_12.htm (38 of 45) [06/04/2000 13:05:57]