16 11 DID numbers, (internal) call number is displayed, (re-)enter call number
16 12 Intercept, day, enter new destination, group or extension number, max. 6 digits
16 13 Intercept, night, enter new destination, group or extension number, max. 6 digits
16 14 Intercept options
16 14 1 On no answer, 0 = no/1 = yes
16 14 2 On busy
16 14 2 1 Intercept, 0 = no/1 = yes
16 14 2 2 Camp on on busy, 0 = no/1 = yes
16 14 3 Intercept on invalid, 0 = no/1 = yes
16 14 4 Intercept on incomplete dialling, 0 = no/1 = yes
16 14 5 Intercept on recall, 0 = no/1 = yes
16 15 Group setup
16 15 1 Group members, select group and assign destination
16 15 2 Group type, select group and type:
1 = Cyclical hunt group
2 = Linear hunt group
3 = Ringing group
4 = Ringing group, all free
16 15 3 Group name, select group and enter names
(optiset E memory only)
16 16 Call allocation, day, select slot/line and assign extension no.
16 17 Call allocation, night, select slot/line and assign extension no.
16 18 CM-Elements
16 18 1 CM-Targets, select list 1-70 and destination index 1-4 and enter extension no. or *
for selected extension or # 9 for search for all extensions
For OfficePro/OfficeCom:
# 201 to # 260 UCD group 01 to 60
# 301 to # 316 announcement device 01 to 16 OfficePro
# 301 to #304 announcement device 01 to 04 OfficeCom
16 18 2 Internal call, select ext./group, 1 to 70
16 18 3 External call, day, select ext./group, 1 to 70
16 18 4 External call, night, select ext./group, 1 to 70
16 18 5 Number of call cycles, select list 1 to 70 and define call cycles
(1 to 15)
16 18 6 Central ring, port, select list 1 to 70 and define ext. or actuator 1 to 4 (*1 - *4)
16 18 7 Central ring, activ., select list 1 to 70,
1 = connect immediately, 2 = after timeout
16 19 Ringing type, 0 = group type 1, 1 = group type 2, 2 = group type 3
16 20 Analogue DID DTMF, 0 = denied/1 = allowed
16 21 Collect protection per CO line
Hicom 150 E Office Rel.1.0 Service Manual - A System programming codes
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_a1.htm (9 of 18) [06/04/2000 13:07:14]