EasyManua.ls Logo

Siemens Hicom 150 E Office - Page 351

Siemens Hicom 150 E Office
672 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 20 to 25 Extension: internal extension number
value range 000000 ... 999999 (missing digits
are replaced by blanks.)
In the case of unanswered calls, the extension
last called is always output (e.g. hunt group,
call forwarding, call forwarding - no answer).
In the case of a group call, this is the extension
last entered. In the case of answered calls, the
subscriber who answered the call is specified.
A programmed No. prefix (only for
networking) is not output.
If internal numbering was translated to a max.
6-digit numbering plan, the translated number
is output.
6 Right
5 26 to 30 Ringing duration of an incoming external call:
mm:ss
(mm = minutes: value range 00 ... 59, ss =
seconds: value range 00 ... 59)
This is displayed for all incoming calls if the
output of the "call duration" has been
configured in the system. When the counter
overflows (duration > 59:59), "59:59" is
displayed. This may occur for example when
changing the date or the time during operation.
6 Left
6 31 to 38 Duration of the call or of the call segment:
hh:mm:ss
(hh = hours: value range 00 ... 23, mm =
minutes: value range 00 ... 59, ss = seconds:
value range 00 ... 59)
If a call was not connected in the case of an
incoming call, 8 blanks are output instead. If
the counter overflows (duration > 23:59:59)
"23:59:59" is output.
8 Left
7 39 to 63 Dialled or, if available, the received external
station number: nnnnnnnnnnnnnnnnnnnnnnnnn
(n = dialled or received character: value range
0 ... 9, *, #, ?)
This is output for incoming and outgoing calls
if available. In the case of outgoing calls the
dialled station number or, if available, the
station number transmitted via COLP is
displayed. If the data protection function has
been activated, the last 4 characters dialled are
replaced with "????". If there is no information
available on the station number, 25 blanks are
output.
25 Left