set inlinepower threshold
5-2 Configuring System Power and PoE
Example
Thisexampleshowshowtodisplaysystempowerproperties:
C2(su)->show inlinepower
Detection Mode : auto
Unit Status Power(W) Consumption(W) Usage(%) Threshold(%) Trap
---- ------ -------- -------------- -------- ------------ ----
1 auto 480 0.00 0.00 80 enable
Table 51providesanexplanationofthecommandoutput.
set inlinepower threshold
Usethiscommandtosetthepowerusagethreshol donaspecifiedunitormodule.
Syntax
set inlinepower threshold usage-threshold module-number
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Table 5-1 show inlinepower Output Details
Output What It Displays...
Detection Mode Displays the PD detection mode used by the switch. The detection mode can be
configured with the command “set inlinepower detectionmode” (page 5-3).
Unit Number of PoE-capable module.
Status Whether the PoE administrative state is off (disabled) or auto (on). This state is not
configurable.
Power (W) Unit’s available power wattage.
Consumption (W) Unit’s power wattage consumed.
Usage (%) Unit’s percentage of total system PoE power usage.
Threshold (%) Unit’s alloted percentage of total PoE power available in the system. The threshold
can be configured with the command “set inlinepower threshold” (page 5-2).
Trap Whether PoE trap messaging is enabled or disabled on this unit. Trap messaging
can be configured with the command “set inlinepower trap” (page 5-3).
usagethreshold Specifiesapowerthresholdasapercentageofavailablesystempower.
Validvaluesare11to100.
modulenumber Specifiesthemoduleorunitonwhichtosetthepowerthreshold.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals