set cdp hold-time
SecureStack C2 Configuration Guide 6-5
Example
ThisexampleshowshowtosettheCDPintervalfrequencyto15seconds:
C2(su)->set cdp interval 15
set cdp hold-time
UsethiscommandtosettheholdtimevalueforCDPdiscoveryprotocolconfigurationmessages.
Syntax
set cdp hold-time hold-time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetCDPholdtimeto60seconds:
C2(su)->set cdp hold-time 60
clear cdp
UsethiscommandtoresetCDPdiscoveryprotocolsettingstodefaults.
Syntax
clear cdp {[state] [port-state port-string] [interval] [hold-time] [auth-code]}
Parameters
Defaults
Atleastoneoptionalparametermustbeentered.
holdtime SpecifiestheholdtimevalueforCDPmessagesinseconds.Validvaluesare
from15to600.
state (Optional)ResetstheglobalCDPstatetoautoenabled.
portstateportstring (Optional) Resetstheportstateonspecificport(s)toautoenabled.
interval (Optional)Resetsthemessagefrequencyintervalto60seconds.
holdtime (Optional)Resetstheholdtimevalueto180seconds.
authcode (Optional)Resetstheauthenticationcodeto16
bytesof00(000000
0000000000).

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals