clear host vlan
SecureStack C2 Configuration Guide 10-19
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
ThehostVLANshouldbeasecureVLANwhereonlydesignatedusersareallowedaccess.For
example,ahostVLANcouldbespecificallycreatedfordevicemanagement.Thiswouldallowa
managementstationconnectedtothemanagementVLANtomanageallportsonthedeviceand
makemanagementsecurebypreventing
managementviaportsassignedtootherVLANs.
Example
ThisexampleshowshowtosetVLAN7asthehostVLAN:
C2(su)->set host vlan 7
clear host vlan
UsethiscommandtoresetthehostVLANtothedefaultsettingof1.
Syntax
clear host vlan
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthehostVLANtothedefaultsetting:
C2(su)->clear host vlan
vlanid SpecifiesthenumberoftheVLAN tosetasthehostVLAN.
Note: Before you can designate a VLAN as the host VLAN, you must create a VLAN using the set
of commands described in “Creating and Naming Static VLANs” on page 10-5.