set pwa maxrequest
23-70 Authentication and Authorization Configuration
Defaults
Ifportstringisnotspecified,quietperiodwillbesetforallports.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthePWAquietperiodto30secondsforportsge.1.57:
C2(su)->set pwa quietperiod 30 ge.1.5-7
set pwa maxrequest
Usethiscommandtosetthemaximumnumberoflogonattemptsallowedbeforetransitioning
thePWAporttoaheldstate.
Syntax
set pwa maxrequests requests [port-string]
Parameters
Defaults
Ifportstringisnotspecified,maximumrequestswillbesetforallports.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthePWAmaximumrequeststo3forallports:
C2(su)->set pwa maxrequests 3
set pwa portcontrol
ThiscommandenablesordisablesPWAauthenticati ononselectports.
Syntax
set pwa portcontrol {enable | disable} [port-string]
maxrequests Specifiesthemaximumnumberoflogonattempts.
portstring (Optional)Setsthemaximumrequestsforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 72.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals