show logging local
SecureStack C2 Configuration Guide 14-9
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoresetthelog gi ngseveritylevelto6forSNMP.
C2(rw)->clear logging application SNMP
show logging local
Usethiscommandtodisplaythestateofmessageloggingtotheconsoleandapersistentfile.
Syntax
show logging local
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaythestateofmessagelogging.Inthi scase,loggingtothe
consoleisenabledandloggingtoapersistentfileisdisabled.
C2(su)->show logging local
Syslog Console Logging enabled
Syslog File Logging disabled
set logging local
Usethiscommandtoconfigurelogmessagestotheconsoleandapersistentfile.
Syntax
set logging local console {enable | disable} file {enable | disable}
mnemonic Resetstheseveritylevelforaspecificapplicationto6.Validmnemonic
valuesandtheircorrespondingapplicationsarelistedinTable 143on
page 148.
all Resetstheseveritylevelforallapplicationsto6.