Setting Speed and Duplex Mode
7-10 Port Configuration
Setting Speed and Duplex Mode
Purpose
ToreviewandsettheoperationalspeedinMbpsandthedefaultduplexmode:Half,forhalf
duplex,orFull,forfullduplexforoneormoreports.
Commands
show port speed
Usethiscommandtodisplaythedefaultspeedsettingononeormoreports.
Syntax
show port speed [port-string]
Parameters
Defaults
Ifportstringisnotspecified,defaultspeedsettingsforallportswilldisplay.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaythedefaultspeedsettingfor1GigabitEthernetport14in
slot 3:
C2(su)->show port speed ge.3.14
default speed is 10 on port ge.3.14.
Note: These settings only take effect on ports that have auto-negotiation disabled.
For information about... Refer to page...
show port speed 7-10
set port speed 7-11
show port duplex 7-11
set port duplex 7-15
portstring (Optional)Displaysdefaultspeedsetting(s)forspecificport(s).Fora
detaileddescriptionofpossibleportstringvalues,referto PortString
SyntaxUsedintheCLIonpage72.