show spantree disputedbpduthreshold
9-52 Spanning Tree Configuration
Example
ThisexampleshowshowtosetthedisputedBPDUthresholdvalueto5:
C2(rw)->set spantree disputedbpduthreshold 5
show spantree disputedbpduthreshold
UsethiscommandtodisplaythecurrentvalueofthedisputedBPDUthreshold.
Syntax
show spantree disputedbpduthreshold
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentdisputedBPDUthreshold:
C2(rw)->show spantree disputedbpduthreshold
The disputed BPDU threshold value is 0
clear spantree disputedbpduthreshold
UsethiscommandtoreturnthedisputedBPDUthresholdtoitsdefaultvalueof0,meaningthat
disputedBPDUtrapsshouldnotbesent.
Syntax
clear spantree disputedbpduthreshold
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresetthedisputedBPDUthresholdtothedefaultof0:
C2(rw)->clear spantree disputedbpduthreshold