show spantree disputedbpduthreshold
9-52 Spanning Tree Configuration
Example
ThisexampleshowshowtosetthedisputedBPDUthresholdvalueto5:
C2(rw)->set spantree disputedbpduthreshold 5
show spantree disputedbpduthreshold
UsethiscommandtodisplaythecurrentvalueofthedisputedBPDUthreshold.
Syntax
show spantree disputedbpduthreshold
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentdisputedBPDUthreshold:
C2(rw)->show spantree disputedbpduthreshold
The disputed BPDU threshold value is 0
clear spantree disputedbpduthreshold
UsethiscommandtoreturnthedisputedBPDUthresholdtoitsdefaultvalueof0,meaningthat
disputedBPDUtrapsshouldnotbesent.
Syntax
clear spantree disputedbpduthreshold
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresetthedisputedBPDUthresholdtothedefaultof0:
C2(rw)->clear spantree disputedbpduthreshold

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals