set logging default
SecureStack C2 Configuration Guide 14-5
Example
ThiscommandshowshowtodisplaytheSyslogserverdefaultvalues.Foranexplanationofthe
commandoutput,referbacktoTable 141onpage 142.
C2(su)->show logging default
Facility Severity Port
-----------------------------------------
Defaults: local4 warning(5) 514
set logging default
Usethiscommandtosetloggingdefaultvalues.
Syntax
set logging default {[facility facility] [severity severity] port port]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheSyslogdefaultfacilitynametolocal2andtheseveritylevelto4
(errorlogging):
C2(su)->set logging default facility local2 severity 4
facilityfacility Specifiesthedefaultfacilityname.Validvaluesare:local0tolocal7.
severityseverity Specifiesthedefaultloggingseveritylevel.Validvaluesand
correspondinglevelsare:
1emergencies(systemisunusable)
2alerts(immediateactionrequired)
3criticalconditions
4errorconditions
5warningconditions
6notifications(significant
conditions)
7informationalmessages
8debuggingmessages
portport SpecifiesthedefaultUDPporttheclientusestosendtothe server.