set rmon event properties
15-14 RMON Configuration
set rmon event properties
UsethiscommandtoconfigureanRMONevententry,ortocreateanewevententrywithan
unusedeventindexnumber.
Syntax
set rmon event properties index [description description] [type {none | log | trap
| both}] [community community] [owner owner]
Parameters
Defaults
Ifdescriptionisnotspecified,nonewillbeapplied.
Ifnotspecified,typenonewillbeapplied.
Ifownerisnotspecified,monitorwillbeapplied.
Mode
Switchcommand,readwrite.
Table 15-3 show rmon event Output Details
Output Field What It Displays...
Index Index number for this event entry.
Owner Text string identifying who configured this entry.
Status Whether this event entry is enabled (valid) or disabled.
Description Text string description of this event.
Type Whether the event notification will be a log entry, and SNMP trap, both, or none.
Community SNMP community name if message type is set to trap.
Last Time Sent When an event notification matching this entry was sent.
index Specifiesanindexnumberforthisentry.Maximumnumberofentriesis
100.Maximumvalueis65535.
description
description
(Optional)Specifiesatextstringdescriptionofthisevent.
typenone|log|
trap|both
(Optional)SpecifiesthetypeofRMONeventnotificationas:none,alog
tableentry,anSNMP
trap,orbothalogentryandatrapmessage.
community
community
(Optional)SpecifiesanSNMPcommunitynametouseifthemessage
typeissettotrap.FordetailsonsettingSNMPtrapsandcommunity
names,refertoCreatingaBasicSNMPTrapConfigurationon
page 837.
ownerowner (Optional)
Specifiesthenameoftheentitythatconfiguredthisentry.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals