EasyManua.ls Logo

Enterasys SecureStack C2 C2G170-24

Enterasys SecureStack C2 C2G170-24
698 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set rmon history
SecureStack C2 Configuration Guide 15-7
Sample 2779 Interval Start: 1 days 0 hours 2 minutes 22 seconds
Drop Events = 0 Undersize Pkts = 0
Octets = 0 Oversize Pkts = 0
Packets = 0 Fragments = 0
Broadcast Pkts = 0 Jabbers = 0
Multicast Pkts = 0 Collisions = 0
CRC Align Errors = 0 Utilization(%) = 0
set rmon history
UsethiscommandtoconfigureanRMONhistoryentry.
Syntax
set rmon history index [port-string] [buckets buckets] [interval interval] [owner
owner]
Parameters
Defaults
Ifbucketsisnotspecified,the maximumnumberofentriesmaintainedwillbe50.
Ifnotspecified,intervalwillbesetto30seconds.
Ifownerisnotspecified,monitorwillbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowconfigureRMONhistoryentry1onportge.2.1tosampleevery20
seconds:
C2(rw)->set rmon history 1 ge.2.1 interval 20
clear rmon history
UsethiscommandtodeleteoneormoreRMONhistoryentriesorresetoneormoreentriesto
defaultvalues.Forspecificvalues,refertosetrmonhistoryonpage 157.
Syntax
clear rmon history {index-list | to-defaults}
indexlist Specifiesanindexnumberforthisentry.
portstring (Optional)Assignsthisentrytoaspecificport.
bucketsbuckets (Optional)Specifiesthemaximumnumberofentriestomaintain.
intervalinterval (Optional)Specifiesthesamplingintervalinseconds.
ownerowner (Optional)Specifiesanownerforthisentry.