set pwa
SecureStack C2 Configuration Guide 23-63
set pwa
Usethiscommandtoenableordisableportwebauthenticati on.
Syntax
set pwa {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoenableportwebauthentication:
C2(su)->set pwa enable
PWA Logo Whether the Enterasys Networks logo will be displayed or hidden at user login.
Default state of enabled (displayed) can be changed using the set pwa displaylogo
command as described in “set pwa displaylogo” on page 23-65.
PWA Guest
Networking Status
Whether PWA guest user status is disabled or enabled with RADIUS or no
authentication. Default state of disabled can be changed using the set pwa
gueststatus command as described in “set pwa gueststatus” on page 23-68.
PWA Guest Name Guest user name for PWA enhanced mode networking. Default value of “guest” can
be changed using the set pwa guestname command as described in “set pwa
guestname” on page 23-67.
PWA Guest
Password
Guest user’s password. Default value of an empty string can be changed using the
set pwa guestpassword command as described inset pwa guestpassword” on
page 23-68.
PWA Redirect Time Time in seconds after login success before the user is redirected to the PWA home
page.
Port PWA port designation.
Mode Whether PWA is enabled or disabled on his port.
Auth Status Whether or not the port state is disconnected, authenticating, authenticated, or held
(authentication has failed).
Quiet Period Amount of time a port will be in the held state after a user unsuccessfully attempts to
log on to the network. Default value of 60 can be changed using the set pwa
quietperiod command as described in “set pwa quietperiod” on page 23-69.
MaxReq Maximum number of log on attempts allowed before transitioning the port to a held
state. Default value of 2 can be changed using the set pwa maxrequests command
as described in “set pwa maxrequest” on page 23-70.
Table 23-8 show pwa Output Details (Continued)
Output Field What It Displays...
enable|disable Enablesordisablesportwebauthentication.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals