Example
Thisexampleshowshowtoassignportsge.1.1throughge.1.3toprotectedportgroup1:
C2(rw)->set port protected ge.1.1-3 1
show port protected
Usethiscommandtodisplayinformationabouttheportsconfiguredforprotectedmode.
Syntax
show port protected [port-string] | [group-id]
Parameters
Defaults
Ifnoparametersareentered,informationaboutallprotectedportsisdisplayed.
Mode
Readonly.
Example
Thisexampleshowshowtodisplayinformationaboutallprotectedports:
C2(ro)->show port protected
Group id Port
----------------------
1 ge.1.1
1 ge.1.2
1 ge.1.3
clear port protected
Usethiscommandtoremoveaportorgroupfromprotectedmode.
Syntax
clear port protected [port-string] | [group-id]
Parameters
Defaults
Ifnoparametersareentered,allprotectedportsandgroupsarecleared.
portstring (Optional)Specifiestheportorportsforwhichtodisplayinformation.
groupid (Optional)Specifiestheidofthegroupforwhichtodisplayinformation.
Idcanrangefrom0to2.
portstring (Optional)Specifiestheportorportstoremovefromprotectedmode.
groupid (Optional)Specifiestheidofthegrouptoremovefromprotectedmode.
Idcanrangefrom0to2.