Preparing a Mixed Stack for IPv6 Proxy Routing
22-2 IPv6 Proxy Routing
Limitations
•Proxyroutingwilluseuptotwomasksinthefastforwardingprocessorassociatedwitheach
portinvolvedinroutingofIPv6packets.Thiswillrequirerestrictionsontheuseofpolicy
whenproxyroutingisenabled.
•AllIPv6packetsingressingoregressingaC2portmustbesentoverthe
stacktotheC3stack
master.LimitedstackbandwidthandtheamountofIPv6trafficmustbecarefullyconsidered
whenconfiguringmultipleC2portsforIPv6routing.
•IfthestackmastermovesfromaC3unittoaC2unitinthestack,proxyroutingwillnolonger
beavailable.To
ensurethatproxyroutingcontinuestooperateintheeventofafailover,C3
unitsmustbeconfiguredtobepreferredwhenanewmasteriselected.
Preparing a Mixed Stack for IPv6 Proxy Routing
AtleasttwoC3switchesshouldbeaddedtoaC2stack,formanagementredundancy.
AsinanymixedC2/C3mixedstack,theC2firmware(release5.01orlater)mustbeinstalledonthe
C3switches.RefertoIssuesRelatedtoMixedTypeStacksonpage 25foradditional
information.
If
youareaddingtheC3switchestoanexisting C2stack,makeoneoftheC3switchesthestack
manager.Forexample,ifthecurrentstackmanagerisunit1andtheC3switchthatyouwantto
becomemanagerisunit7:
C2(su)->set switch movemenagement 1 7
Moving stack management will unconfigure entire stack including all interfaces.
Are you sure you want to move stack management? (y/n) y
SetthemanagementpriorityoftheC3swi tchestobehigherthanthatoftheC2switches.For
example,ifyourC3switchesareunits7and8,andyouwanttheunit7C3switchtoalways
becomethemanagerandtheunit8C3switchtobethebackup
manager:
C2(su)->set switch 7 priority 15
C2(su)->set switch 8 priority 13
Usetheshowswitchunitcommandtodisplayswitchpriority(AdminManagementPreference).
C2(su)->show switch 7
Switch 7
Management Status Management Switch
Hardware Management Preference Unassigned
Admin Management Preference 15
Switch Type C3G124-48
Preconfigured Model Identifier C3G124-48
Plugged-in Model Identifier C3G124-48
Switch Status OK
Switch Family XGS3
Switch Description
Detected Code Version 05.02.00.0031
Detected Code in Flash 05.02.00.0031
Detected Code in Back Image 05.01.06.0006
Up Time 0 days 0 hrs 13 mins 9 secs

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals