EasyManua.ls Logo

Enterasys SecureStack C2 C2G170-24 - Set Switch

Enterasys SecureStack C2 C2G170-24
698 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
set switch
SecureStack C2 Configuration Guide 2-9
Parameters
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaydataanderrorinformationonstackports:
C2(ro)->show switch stack-ports
------------TX-------------- ------------RX-----------
Data Error Data Error
Stacking Rate Rate Total Rate Rate Total
Switch Port (Mb/s) (Errors/s) Errors (Mb/s) (Errors/s) Errors
------ ---------- ------ ---------- ---------- ------ ---------- --------
1 Up 0 0 0 0 0 0
Down 0 0 0 0 0 0
set switch
UsethiscommandtoassignaswitchID,tosetaswitch’spriorityforbecomingthemanagement
switchifthepreviousmanagementswitchfails,ortochangetheswitchunitIDforaswitchinthe
stack.
Syntax
set switch {unit [priority value | renumber newunit]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
unit (Optional)SpecifiestheswitchunitID,anintegerrangingfrom1to8.
unit Specifiesaunitnumberfortheswitch.Valuecanrangefrom1to8.
priorityvalue Specifiesapriorityvaluefortheunit.Validvaluesare1to15withhigher
valuesassigninghigherpriority.
renumbernewunit Specifiesanewnumberfortheunit.
Note: This number must be a previously unassigned unit ID number.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Related product manuals