EasyManua.ls Logo

Enterasys SecureStack C2 C2G170-24 - Installing Previously-Configured Systems in a Stack; Adding a New Unit to an Existing Stack; Creating a Virtual Switch Configuration

Enterasys SecureStack C2 C2G170-24
698 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing Previously-Configured Systems in a Stack
SecureStack C2 Configuration Guide 2-3
Installing Previously-Configured Systems in a Stack
Ifmemberunitsinastackhavebeenpreviousmembersofadifferentstack,youmayneedto
configuretherenumberingofthestackasfollows:
1. Stacktheunitsinthemethoddesired,and connectthestackcables.
2. Poweruponlytheunityouwishtobemanager.
3. Oncethemanagementunit
ispoweredup,logintotheCLI,and usetheshowswitch
commandasdescribedin“showswitch”onpage2‐6todisplaystackinginformation.
4. Clearanyswitcheswhicharelistedas“unassigned”usingtheclearswitchmember
commandasdescribedin“clearswitchmember”onpage2
‐12.
5. Powerupthememberofthestackyouwishtobecomeunit2.Oncethesecondunitisfully
powered,theCOMsessionoftheCLIwillstatethatanewCPUwasadded.
6. Usetheshowswitchcommandtoredisplaystackinginformation.
a. Ifthenewmemberdisplaysasunit
2,youcanproceedtorepeatthisstepwiththenext
unit.
b. Ifthenewmemberdisplaysadifferentunitnumber,youmust:
(1) Renumberthestackusingthesetswitchrenumbercommandasdescribedin“set
switch”onpage2‐9,then
(2) Cleartheoriginalunitnumberusingtheclear
switchmembercommand.
7. RepeatStep6untilallmembershavebeenrenumberedintheorderyoudesire.
8. Afterthestackhasbeenreconfigured,youcanusetheshowswitchunitcommand(“show
switch”onpage2‐6)tophysicallyconfirmtheidentityofeachunit.Whenyouenterthe
command
withaunitnumber,theMGRLEDofthespecifiedswitchwillblinkfor10seconds.
ThenormalstateofthisLEDisoffformemberunitsandsteadygreenforthemanagerunit.
Adding a New Unit to an Existing Stack
Usethefollowingprocedureforinstallinganewunittoanexistingstackconfiguration.This
procedureassumesthatthenewunitbeingaddedhasacleanconfigurationfrommanufacturing
andisrunningthesamefirmwareimageversionasotherunitsinthestack.
1. Ensurethatpowerisoffonthenew
unitbeinginstalled.
2. Useoneofthefollowingmethodstocompletestackcableconnections:
–Iftherunningstackusesadaisychaintopology,makethestackcableconnectionsfrom
thebottomofthestacktothenewunit(thatis,STACKDOWNportfromthebottomunit
oftherunningstackto
theSTACKUPportonthenewunit).
–Iftherunningstackusesaringstacktop ology,breaktheringandmakethestackcable
connectionstothenewunittoclosethering.
3. Applypowertothenewunit.
Creating a Virtual Switch Configuration
YoucancreateaconfigurationforaSecureStackC2switchbeforeaddingtheactualphysical
devicetoastack.Thispreconfigurationfeatureincludesconfiguringprotocolsontheportsofthe
“virtualswitch.”

Table of Contents