show dot1x auth-config
SecureStack C2 Configuration Guide 23-13
show dot1x auth-config
Usethiscommandtodisplay802.1Xauthenticationconfigurationsettingsforoneormoreports.
Syntax
show dot1x auth-config [authcontrolled-portcontrol] [maxreq] [quietperiod]
[reauthenabled] [reauthperiod] [servertimeout] [supptimeout] [txperiod]
[port-string]
Parameters
Defaults
Ifnoparametersarespecified,all802.1Xsettingswillbedisplayed.
Ifportstringisnotspecified,informationforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Examples
ThisexampleshowshowtodisplaytheEAPOLportcontrolmodeforfe.1.1:
C2(su)->show dot1x auth-config authcontrolled-portcontrol fe.1.1
Port 1: Auth controlled port control: Auto
Thisexampleshowshowtodisplaythe802.1Xquietperiodsettingsforfe.1.1:
C2(su)->show dot1x auth-config quietperiod fe.1.1
Port 1: Quiet period: 30
Thisexampleshowshowtodisplayall802.1Xauthenti cationconfigurationsettingsforge.1.1:
C2(ro)->show dot1x auth-config ge.1.1
authcontrolled
portcontrol
(Optional)DisplaysthecurrentvalueofthecontrolledPortcontrol
parameterfortheport.
maxreq (Optional)Displaysthevaluesetformaximumrequestscurrently inuseby
thebackendauthenticationstatemachine.
quietperiod (Optional)Displaysthevaluesetforquietperiodcurrentlyinusebythe
authenticatorPAEstatemachine.
reauthenabled (Optional)
Displaysthestateofreauthenticationcontrolusedbythe
ReauthenticationTimerstatemachine.
reauthperiod (Optional)Displaysthevalue,inseconds,setforthereauthentication
periodusedbythereauthenticationtimerstatemachine.
servertimeout (Optional)Displaystheservertimeoutvalue,inseconds,currentlyinuse
bythebackendauthenticationstatemachine.
supptimeout (Optional)Displaysthe
authenticationsupplicanttimeoutvalue,in
seconds,currentlyinusebythebackendauthenticationstatemachine.
txperiod (Optional)Displaysthetransmissionperiodvalue,inseconds,currentlyin
usebytheauthenticatorPAEstatemachine.
portstring (Optional)Limitsthedisplayofdesiredinformationinformationtospecific
port(s).Foradetaileddescriptionofpossible
portstringvalues,referto
PortStringSyntaxUsedintheCLIonpage 72.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals