set system lockout
3-8 Basic Configuration
Parameters
None.
Defaults
None.
Mode
Switchcommand,superuser.
Example
Thisexampleshowshowtodisplayuserlockoutsettings.Inthiscase,switchdefaultshavenot
beenchanged:
C2(su)->show system lockout
Lockout attempts: 3
Lockout time: 15 minutes.
Table 33providesanexplanationofthecommandoutput.Thesesettingsareconfiguredwiththe
setsystemlockoutcommand(“setsystemlockoutonpage38).
set system lockout
Usethiscommandtosetthenumberoffailedloginattemptsbeforelockingout(disabling)aread
writeorreadonlyuseraccount,andthenumberofminutestolock outthedefaultadminsuper
useraccountaftermaximumloginattempts.
Syntax
set system lockout {[attempts attempts] [time time]}
Parameters
Defaults
None.
Mode
Switchcommand,superuser.
Table 3-3 show system lockout Output Details
Output Field What It Displays...
Lockout attempts Number of failed login attempts allowed before a read-write or read-only user’s
account will be disabled.
Lockout time Number of minutes the default admin user account will be locked out after the
maximum login attempts.
attemptsattempts Specifiesthenumberoffailedloginattemptsallowedbeforeareadwrite
orreadonlyusersaccountwillbedisabled.Validvaluesare1to10.
timetime Specifiesthenumberofminutesthedefaultadminuseraccountwillbe
lockedoutafterthemaximumloginattempts.Validvaluesare
0to60.