show port inlinepower
5-4 Configuring System Power and PoE
Parameters
Defaults
Defaultdetectionmodeisauto.
Mode
Switchcommand,readwrite.
Usage
ThiscommandisusedtospecifyhowtheswitchshoulddetectPDsconnectedtoitsports.ThePoE
hardwareintheswitchescanusetheIEEEstandard802.3af(resist o rbased)methodora
proprietarymethodusingcapacitordetection.
Ifautoisconfigured,theswitchwillfirstusetheIEEEresistorbased
detectionmethod,andifthat
fails,theswitchwillusethecapacitorbaseddetectionmethod.Ifieeeisconfigured,onlytheIEEE
resistorbaseddetectionmethodwillbeused.
Example
Thisexamplesetstheswitch’s PDdetectionmodetoIEEEstandard802.3afonly.
C2
(su)->set inlinepower detectionmode ieee
show port inlinepower
Usethiscommandtodisplayallportssupporting PoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
Ifnotspecified,informationforallPoEportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplayPoEinformationforportge.2.1.Inthiscase,theport’s
administrativestate,PoEpriorityandclasshavenotbeenchangedfromdefaultvalues:
auto Specifiesthattheswitchwillusethestandard802.3afdetectionmethod
first.Ifthatfails,thentheswtichwillusethelegacy(pre802.3af
standard)capacitancemethodofdetection.
ieee Specifiesthatthe
switchwillonlythestandard802.3afdetection
method.
portstring (Optional)DisplaysinformationforspecificPoEport(s).