ping
14-14 Logging and Network Management
ping
UsethiscommandtosendICMPechorequestpacketstoanothernodeonthe networkfromthe
switchCLI.
Syntax
ping host
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Examples
ThisexampleshowshowtopingIPaddress134.141.89.29.Inthiscase,thishostisalive:
C2(su)->ping 134.141.89.29
134.141.89.29 is alive
Inthisexample,thehostatIPaddressisnotresponding:
C2(su)->ping 134.141.89.255
no answer from 134.141.89.255
show users
UsethiscommandtodisplayinformationabouttheactiveconsoleportorTelnetsession(s)logged
intotheswitch.
Syntax
show users
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtousetheshowuserscommand.Inthisoutput,therearetwoTelnet
usersloggedinwithReadWriteaccessprivilegesfromIPaddresses134.141.192.119and
134.141.192.18:
host SpecifiestheIPaddressofthedevicetowhichthepingwillbesent.