set spantree backuproot
9-22 Spanning Tree Configuration
set spantree backuproot
UsethiscommandtoenableordisabletheSpanningTreebackuprootfunctionontheswitch.
Syntax
set spantree backuproot sid {disable | enable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
TheSpanningTreebackuprootfunctionisdisabledbydefaultontheSecureStackC2.Whenthis
featureisenabledandtheswitchisdirectlyconnectedtotherootbridge,staleSpanningTree
informationispreventedfromcirculatingiftherootbridgeislost.Iftherootbridgeislost,the
backup
rootwilldynamicallyloweritsbridgeprioritysothatitwillbeselectedasthenewroot
overthelostrootbridge.
Example
ThisexampleshowshowtoenablethebackuprootfunctiononSID2:
C2(rw)->set spantree backuproot 2 enable
clear spantree backuproot
UsethiscommandtoresettheSpanningTreebackuprootfunctiontothedefaultstateofdisabled.
Syntax
clear spantree backuproot sid
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
sid SpecifiestheSpanningTreeinstanceonwhichtoenableordisablethe
backuprootfunction.Validvaluesare0‐4094.
disable|enable Enablesordisablesthebackuprootfunction.
sid SpecifiestheSpanningTreeonwhichtoclearthebackuproot
function.Validvaluesare0‐4094.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals