set logout
SecureStack C2 Configuration Guide 3-29
Example
ThisexampleshowshowtodisplaytheCLIlogoutsetting:
C2(su)->show logout
Logout currently set to: 10 minutes.
set logout
Usethiscommandtosetthetime(inminutes)anidleconsoleorTelnetCLIsessionwillremain
connectedbeforetimingout.
Syntax
set logout timeout
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtosetthesystemtimeoutto10minutes:
C2(su)->set logout 10
show console
Usethiscommandtodisplayconsolesettings.
Syntax
show console [baud] [bits] [flowcontrol] [parity] [stopbits]
Parameters
Defaults
Ifnoparametersarespecified,allsettingswillbedisplayed.
timeout Setsthenumberofminutesthesystemwillremainidlebeforetimingout.
baud (Optional)Displaystheinput/outputbaudrate.
bits (Optional)Displaysthenumberofbitspercharacter.
flowcontrol (Optional)Displaysthetypeofflowcontrol.
parity (Optional)Displaysthetypeofparity.
stopbits (Optional)Displaysthenumberofstopbits.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals