EasyManua.ls Logo

Enterasys SecureStack C2 C2G170-24

Enterasys SecureStack C2 C2G170-24
698 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
clear snmp notify
8-32 SNMP Configuration
command’stagparametercanbeusedtobindeachentrytoatargetaddressusingthesetsnmp
targetaddrcommand(“setsnmptargetaddronpage 826).
Syntax
set snmp notify notify tag tag [trap | inform] [volatile | nonvolatile]
Parameters
Defaults
Ifnotspecified,messagetypewillbesettotrap.
Ifnotspecified,storagetypewillbesettononvolatile.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetanSNMPnotifyconfigurationwithanotifynameof“hello”anda
notifytagof“world”.Notificationswillbesentastrapmessagesandstoragetypewill
automaticallydefaulttopermanent:
C2(su)->set snmp notify hello tag world trap
clear snmp notify
UsethiscommandtoclearanSNMPnotifyconfiguration.
Syntax
clear snmp notify notify
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
notify SpecifiesanSNMPnotifyname.
tagtag SpecifiesanSNMPnotifytag.ThisbindsthenotifynametotheSNMP
targetaddresstable.
trap|inform (Optional)SpecifiesSNMPv1orv2Trapmessages(default)orSNMPv3
InformRequestmessages.
volatile|
nonvolatile
(Optional)Specifiestemporary(default),orpermanentstorage
forSNMP
entries.
notify SpecifiesanSNMPnotifynametoclear.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Related product manuals