set logging server
SecureStack C2 Configuration Guide 14-3
set logging server
UsethiscommandtoconfigureaSyslogserver.
Syntax
set logging server index [ ip-addr ip-addr] [facility facility] [severity severity]
[descr descr] [port port] [state {enable | disable}]
Parameters
Defaults
Ifipaddrisnotspecified,an entryintheSyslogservertablewillbecreatedwiththespecified
indexnumberandamessagewilldisplayindicatingthatnoIPaddresshasbeenassigned.
Ifnotspecified,facility,severityandportwillbesettodefaultsconfiguredwiththesetlogging
defaultcommand(“setloggingdefaultonpage 145).
Ifstateisnotspecified,the serverwillnotbeenabledordisabled.
Mode
Switchcommand,readwrite.
index Specifiestheservertableindexnumberforthisserver.Validvaluesare1‐
8.
ipaddripaddr (Optional)SpecifiestheSyslogmessageserversIPaddress.
facilityfacility (Optional)Specifiestheserversfacilityname.Validvaluesare:local0to
local7.
severityseverity (Optional)Specifiestheseveritylevelatwhich
theserverwilllog
messages.Validvaluesandcorrespondinglevelsare:
1emergencies(systemisunusable)
2alerts(immediateactionrequired)
3criticalconditions
4errorconditions
5warningconditions
6notifications(significantconditions)
7informationalmessages
8debuggingmessages
descrdescr (Optional)Specifiesatextualstring
descriptionofthisfacility/server.
portport (Optional)SpecifiesthedefaultUDPporttheclientusestosendtothe
server.
stateenable|
disable
(Optional)Enablesordisablesthisfacility/serverconfiguration.