set spantree mstmap
9-14 Spanning Tree Configuration
set spantree mstmap
UsethiscommandtomaponeormorefilteringdatabaseIDs(FIDs)toaSID.SinceVLANsare
mappedtoFIDs,thisessentiallymapsoneormoreVLANIDstoaSpanningTree(SID).
Syntax
set spantree mstmap fid [sid sid]
Parameters
Defaults
Ifsidisnotspecified,FID(s)willbemappedtoSpanningTree0.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtomapFID3toSID2:
C2(su)->set spantree mstmap 3 sid 2
clear spantree mstmap
UsethiscommandtomapaFIDbacktoSID0.
Syntax
clear spantree mstmap fid
Parameters
Defaults
Iffidisnotspecified,allSIDtoFIDmappingswillbereset.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtomapFID2backtoSID0:
Note: Since any MST maps that are associated with GVRP-generated VLANs will be removed from
the configuration if GVRP communication is lost, it is recommended that you only create MST maps
on statically-created VLANs.
fid SpecifiesoneormoreFIDstoassigntotheMST.Validvaluesare1‐4093,
andmustcorrespondtoaVLANIDcreatedusingthesetvlancommand.
sidsid (Optional)SpecifiesaMultipleSpanningTreeID.Validvaluesare1‐4094,
andmustcorrespondtoaSIDcreated
usingthesetmsticommand.
fid SpecifiesoneormoreFIDstoresetto0.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals