show snmp notifyprofile
SecureStack C2 Configuration Guide 8-35
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtodeletetheSNMPnotifyfilter“pilot1”:
C2(su)->clear snmp notifyfilter pilot1 subtree 1.3.6
show snmp notifyprofile
UsethiscommandtodisplaySNMPnotifyprofileinformation.Thisassociatestarget parameters
toanSNMPnotifyfiltertodeterminewhoshouldnotreceiveSNMPnotifications.
Syntax
show snmp notifyprofile [profile] [targetparam targetparam] [volatile |
nonvolatile | read-only]
Parameters
Defaults
Ifnoparametersarespecified,allnotifyprofileinformationwillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaySNMPnotifyinformationfortheprofilenamed“area51”:
C2(su)->show snmp notifyprofile area51
--- SNMP notifyProfile information ---
Notify Profile = area51
TargetParam = v3ExampleParams
Storage type = nonVolatile
profile SpecifiesanSNMPfilternotifynametodelete.
subtreeoidor
mibobject
SpecifiesaMIBsubtreeIDcontainingthefiltertobedeleted.
profile (Optional)Displaysaspecificnotifyprofile.
targetparam
targetparam
(Optional)Displaysentriesforaspecifictargetparameter.
volatile|
nonvolatile|read
only
(Optional)Displaysnotifyfilterentriesofaspecificstoragetype.