set pwa initialize
SecureStack C2 Configuration Guide 23-69
Usage
PWAwilluseaguestpasswordandguestusernametograntnetworkaccesswithdefaultpolicy
privilegestouserswithoutestablishedloginnamesandpasswords.
Example
ThisexampleshowshowtoenablePWAguestnetworkingwithRADIUSauthentication:
C2(su)->set pwa guestnetworking authradius
set pwa initialize
UsethiscommandtoinitializeaPWAporttoitsdefaultunauthenticatedstate.
Syntax
set pwa initialize [port-string]
Parameters
Defaults
Ifportstringisnotspecified,allportswillbeinitialized.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoinitializeportsge.1.57:
C2(su)->set pwa initialize ge.1.5-7
set pwa quietperiod
Usethiscommandtosettheamountoftimeaportwillremainintheheldstateafterauser
unsuccessfullyattemptstologontothenetwork.
Syntax
set pwa quietperiod time [port-string]
Parameters
portstring (Optional)Initializesspecificport(s).Foradetaileddescriptionofpossible
portstringvalues,refertoPortStringSyntaxUsedintheCLIon
page 72.
time Specifiesquiettimeinseconds.
portstring (Optional)Setsthequietperiodforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 72.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals