set pwa initialize
SecureStack C2 Configuration Guide 23-69
Usage
PWAwilluseaguestpasswordandguestusernametograntnetworkaccesswithdefaultpolicy
privilegestouserswithoutestablishedloginnamesandpasswords.
Example
ThisexampleshowshowtoenablePWAguestnetworkingwithRADIUSauthentication:
C2(su)->set pwa guestnetworking authradius
set pwa initialize
UsethiscommandtoinitializeaPWAporttoitsdefaultunauthenticatedstate.
Syntax
set pwa initialize [port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,allportswillbeinitialized.
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtoinitializeportsge.1.5‐7:
C2(su)->set pwa initialize ge.1.5-7
set pwa quietperiod
Usethiscommandtosettheamountoftimeaportwillremainintheheldstateafterauser
unsuccessfullyattemptstologontothenetwork.
Syntax
set pwa quietperiod time [port-string]
Parameters
port‐string (Optional)Initializesspecificport(s).Foradetaileddescriptionofpossible
port‐stringvalues,referto“PortStringSyntaxUsedintheCLI”on
page 7‐2.
time Specifiesquiettimeinseconds.
port‐string (Optional)Setsthequietperiodforspecificport(s).Foradetailed
descriptionofpossibleport‐stringvalues,referto“PortStringSyntaxUsed
intheCLI”onpage 7‐2.