clear cos reference
SecureStack C2 Configuration Guide 11-33
Parameters
Defaults
Ifirlisnotspecified,allCoSreferenceinformationisdisplayed.
Ifaspecificportgroupisnotspecified,informationfor allportgroupsisdisplayed.
Mode
Switchcommand,read‐only.
Example
ThisexampleshowstheClassofServiceIRLreferencesforportgroup1.0.Notethatnotallofthe
100possiblereferencesaredisplayedinthisoutputexample.
C2(su)->show cos reference irl 1.0
Group Index Reference Type Rate Limiter
----------- --------- ---- ------------
1.0         0         irl  none
1.0         1         irl  1         
1.0         2         irl  none
1.0         3         irl  none
...
1.0         97        irl  none
1.0         98        irl  none
1.0         99        irl  none
clear cos reference
UsethiscommandtocleartheClassofServiceinboundratelimitingreferenceconfiguration.
Syntax
clear cos reference irl {all | group-type-index reference}
Parameters
irl (Optional)Specifiesthatinboundratelimitingreferenceinformation 
shouldbedisplayed.
group‐type‐index (Optional)Specifiesaninboundratelimitingportgroup/typeindex.Valid
entriesareintheformofgroup#.port‐type.
Validvaluesforgroup#canrangefrom0to7.Validvaluesforport‐type
canrangefrom0
to1,althoughonlyporttype 0 iscurrentlysupported.
Forexample,portgroup3wouldbespecifiedas3.0.
irl SpecifiesthatIRLreferencesarebeingcleared.
all Clearallgroupsindexesandreferences.