set rmon alarm status
SecureStack C2 Configuration Guide 15-11
Defaults
interval‐3600seconds
type‐absolute
startup‐rising
rthresh‐0
fthresh‐0
revent‐0
fevent‐0
owner‐monitor
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoconfigurearisingRMONalarm.Thisentrywillconductmonitoring
ofthedeltabetweensamplesevery30seconds:
C2(rw)->set rmon alarm properties 3 interval 30 object
1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager
set rmon alarm status
UsethiscommandtoenableanRMONalarmentry.Analarmisanotificationthatastatistical
sampleofamonitoredvariablehascrossedaconfiguredthreshold.
Syntax
set rmon alarm status index enable
startuprising|
falling|either
(Optional)Specifiesthetypeofalarmgeneratedwhenthiseventisfirst
enabledas:
Rising‐SendsalarmwhenanRM ONeventreachesamaximum
thresholdconditionisreached,forexample,morethan30collisions
persecond.
•Falling‐SendsalarmwhenRMONeventfallsbelowaminimum
thresholdcondition,forexamplewhenthenetworkisbehaving
normallyagain.
•Either‐Sendsalarmwheneitherarisingorfallingthresholdis
reached.
rthreshrthresh (Optional)Specifiesaminimumthresholdforcausingarisingalarm.
fthreshfthresh Specifiesamaximumthresholdforcausingafallingalarm.
reventrevent Specifiestheindexnumberofthe
RMONeventtobet riggeredwhenthe
risingthresholdiscrossed.
feventfevent SpecifiestheindexnumberoftheRMONeventtobetriggeredwhenthe
fallingthresholdiscrossed.
ownerowner (Optional)Specifiesthenameoftheentitythatconfiguredthisalarm
entry.