clear system temperature
3-18 Basic Configuration
Usage
Ontheplatformsthatsupportthisfeature,temperaturesensorsarelocatedinseveraldifferent
locationswithinthedevice.Thresholdcalibrationshavebeencalculatedseparatelyforeach
platform.Thethermalovertempthresholdisthehighwatermarkthat,whenreached,triggersan
alerttowarnthesy stemadministratorthatthedeviceis
operatingathightemperatures.
Thevaluessetwiththiscommandcanbeviewedwiththeshowsystemcommand.
RefertotheReleaseNoteforyourplatformtodetermineifthisfeatureissupportedonyour
platform.
Example
ThefollowingexampleenablessendingSNMPtrapsandsetstheovertempthresholdto60%.
C2(su)->set system temperature trap enable overtemp-threshold 60
clear system temperature
Usethiscommandtoresetsystemhightemperatureparameterstotheirdefaultvalues,onthe
platformsthatsupportthisfeature.
Syntax
clear system temperature
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thiscommandresetsallthehightemperatureparameterstotheirdefaultvalues:
•Syslogalertsaredisabledbydefault.
•Trapalertsaredisabledbydefault.
•Overtempthresholdis100%bydefault.
Example
Thisexampleresetsallhightemperatureparameterstotheirdefaults.
C2(su)->clear system temperature

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals