set spantree adminedge
SecureStack C2 Configuration Guide 9-39
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforge.3.2:
C2(su)->show spantree adminedge port ge.3.2
Port
ge.3.2 has a Port Admin Edge of Edge-Port
set spantree adminedge
UsethiscommandtosettheedgeportadministrativestatusonaSpanningTreeport.
Syntax
set spantree adminedge port-string {true | false}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thedefaultbehavioroftheedgeportadministrativestatusbeginswiththevaluesettofalse
initiallyafterthedeviceispoweredup.IfaSpanningTreeBDPUisnotreceivedontheportwithin
afewseconds,thestatussettingchangestotrue.
Example
Thisexampleshowshowtosetge.1.11asanedgeport:
C2(su)->set spantree adminedge ge.1.11 true
clear spantree adminedge
UsethiscommandtoresetaSpanningTreeporttononedgestatus.
Syntax
clear spantree adminedge port-string
portstring Specifiestheedgeport.Foradetaileddescriptionofpossibleportstring
values,refertoPortStringSyntaxUsedintheCLIonpage 72.
true|false Enables(true)ordisables(false)thespecifiedportasaSpanningTreeedge
port.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals