set snmp notifyfilter
8-34 SNMP Configuration
set snmp notifyfilter
UsethiscommandtocreateanSNMPnotifyfilterconfiguration.Thisidentifieswhich
managementtargetsshouldNOTreceivenotificationmessages,whichisusefulforfinetuningthe
amountofSNMPtrafficgenerated.
Syntax
set snmp notifyfilter profile subtree oid-or-mibobject [mask mask] [included |
excluded] [volatile | nonvolatile]
Parameters
Defaults
Ifnotspecified,maskisnotset.
Ifnotspecified,subtreewillbeincluded.
Ifstoragetypeisnotspecified,nonvolatile(permanent)willbeapplied.
Mode
Switchcommand,readwrite.
Usage
SeeAboutSNMPNotifyFiltersonpage 828formoreinformationaboutnotifyfilters.
Example
Thisexampleshowshowtocreatean SNMPnotifyfiltercalled“pilot1”withaMIBsubtreeIDof
1.3.6:
C2(su)->set snmp notifyfilter pilot1 subtree 1.3.6
clear snmp notifyfilter
UsethiscommandtodeleteanSNMPnotifyfilterconfiguration.
Syntax
clear snmp notifyfilter profile subtree oid-or-mibobject
profile SpecifiesanSNMPfilternotifyname.
subtreeoidor
mibobject
SpecifiesaMIBsubtreeIDtargetforthefilter.
maskmask (Optional)Appliesasubtreemask.
included|
excluded
(Optional)Specifiesthatsubtreeisincludedorexcluded.
volatile|
nonvolatile
(Optional)Specifiesastoragetype.