set port vlan
SecureStack C2 Configuration Guide 10-9
ge.2.5 is set to 1
ge.2.6 is set to 1
set port vlan
UsethiscommandtoconfigurethePVID(portVLANidentifier)foroneormoreports.
Syntax
set port vlan port-string pvid [modify-egress | no-modify-egress]
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
ThePVIDisusedtoclassifyuntaggedframesastheyingressintoagivenport.
Example
Thisexampleshowshowtoaddge.1.10totheportVLANlistofVLAN4(PVID4).
C2(su)->set vlan create 4
C2(su)->set port vlan ge.1.10 4 modify-egress
clear port vlan
Usethiscommandtoresetaport’s802.1QportVLANID(PVID)tothehostVLANID1.
Syntax
clear port vlan port-string
portstring Specifiestheport(s) forwhichtoconfigureaVLANidentifier.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage 72.
pvid Specifies theVLANIDoftheVLANtowhichport(s)willbeadded.
modifyegress (Optional)Addsport(s)
toVLANʹsuntaggedegresslistandremovesthem
fromotheruntaggedegresslists.
nomodifyegress (Optional)Doesnotpromptforormakeegresslistchanges.
Note: The following command will reset the specified port’s egress status to tagged. To set the
specified ports back to the default egress status of untagged, you must issue the set port vlan
command as described on page 10-9.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals