clear logging local
14-10 Logging and Network Management
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thiscommandshowshowtoenableloggingtotheconsoleanddisableloggingtoapersistentfile:
C2(su)->set logging local console enable file disable
clear logging local
Usethiscommandtocleartheconsoleandpersistentstoreloggingforthe localsession.
Syntax
clear logging local
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoclearloca llogging:
C2(su)->clear logging local
show logging buffer
Usethiscommandtodisplaythelast256messageslogged.Bydefault,criticalfailuresanduser
loginandlogoutti mestampsaredisplayed.
Syntax
show logging buffer
Parameters
None.
consoleenable|disable Enablesordisablesloggingtotheconsole.
fileenable|disable Enablesordisablesloggingtoapersistentfile.