show spantree spanguardtimeout
SecureStack C2 Configuration Guide 9-27
show spantree spanguardtimeout
UsethiscommandtodisplaytheSpanningTreeSpanGuardtimeoutsetting.
Syntax
show spantree spanguardtimeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaytheSpanGuardtimeoutsetting:
C2(su)->show spantree spanguardtimeout
Spanguard timeout: 300
set spantree spanguardtimeout
Usethiscommandtosettheamountoftime(inseconds)anedgeportwillremainlockedbythe
SpanGuardfunction.
Syntax
set spantree spanguardtimeout timeout
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheSpanGuardtimeoutto600seconds:
C2(su)->set spantree spanguardtimeout 600
timeout Specifiesatimeoutvalueinseconds.Validvaluesare0to65535.
Avalueof0willkeeptheportlockeduntilmanuallyunlocked.Thedefault
valueis300seconds.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals