clear spantree lpwindow
SecureStack C2 Configuration Guide 9-49
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectwindowvalue:
C2(rw)->show spantree lpwindow
The Loop Protect event window is set to 120 seconds
clear spantree lpwindow
UsethiscommandtoresettheLoopProtecteventwindowtothedefaultvalueof180seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheLoopProtecteventwindowtothedefaultof180seconds:
C2(rw)->clear spantree lpwindow
set spantree lptrapenable
UsethiscommandtoenableordisableLoopProtecteventnotification.
Syntax
set spantree lptrapenable {enable | disable}