show port mirroring
SecureStack C2 Configuration Guide 7-35
show port mirroring
Usethiscommandtodisplaythesourceandtargetportsformirroring,andwhethermirroringis
currentlyenabledordisabledforthoseports.
Syntax
show port mirroring
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplayportmirroringinformation.Inthiscase,ge.1.4isconfigured
asasourceportandge.1.11isatargetandmirroringhasbeenenabledbetweentheseports:
C2(su)->show port mirroring
Port Mirroring
==============
Source Port =
ge.1.4
Target Port = ge.1.11
Frames Mirrored = Rx and Tx
Port Mirroring status enabled.
set port mirroring
Usethiscommandtocreateanewmirroringrelationshiportoenableordisableanexisting
mirroringrelationshipbetweentwoports.
Syntax
set port mirroring {create | disable | enable} source destination}
Notes: When a port mirror is created, the mirror destination port is removed from VLAN 1’s egress
list after a reboot.
"MAC addresses will be learned for packets tagged with the mirror VLAN ID. This will prevent the
ability to snoop traffic across multiple hops.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals