EasyManuals Logo

Enterasys SecureStack C2 C2G170-24 User Manual

Enterasys SecureStack C2 C2G170-24
698 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
show port counters
SecureStack C2 Configuration Guide 7-5
show port counters
Usethiscommandtodisplayportcounterstatisticsdetailingtrafficthroughthedeviceand
throughallMIB2networkdevices.
Syntax
show port counters [port-string] [switch | mib2]
Parameters
Defaults
Ifportstringisnotspecified,counterstatisticswillbedisplayedforallports.
Ifmib2orswitcharenotspecified,allcounterstatisticswillbedisplayedforthespecifiedport(s).
Mode
Switchcommand,readonly.
Examples
Thisexampleshowshowtodisplayallcounterstatistics,includingMIB2networktrafficand
trafficthroughthedeviceforge.3.1:
C2(su)->show port counters ge.3.1
Port: ge.3.1 MIB2 Interface: 1
Table 7-1 show port status Output Details
Output Field What It Displays...
Port Port designation. For a detailed description of possible port-string values, refer to
Port String Syntax Used in the CLI” on page 7-2.
Alias (truncated) Alias configured for the port. For details on using the set port alias command, refer
to “set port alias” on page 7-8.
Oper Status Operating status (up or down).
Admin Status Whether the specified port is enabled (up) or disabled (down). For details on using
the set port disable command to change the default port status of enabled, refer to
set port disable” on page 7-7. For details on using the set port enable command to
re-enable ports, refer to “set port enable” on page 7-7.
Speed Operational speed in Mbps or Kbps of the specified port. For details on using the set
port speed command to change defaults, refer to “set port speed” on page 7-11.
Duplex Duplex mode (half or full) of the specified port. For details on using the set port
duplex command to change defaults, refer to “Setting Auto-Negotiation and
Advertised Ability” on page 7-15.
Type Physical port and interface type.
portstring (Optional)Displayscounterstatisticsforspecificport(s).Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLIonpage72.
switch|mib2 (Optional)DisplaysswitchorMIB2statistics. Switchstatisticsdetail
performanceoftheSecureStackC2device.MIB2
interfacestatisticsdetail
performanceofallnetworkdevices.

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals