clear linkflap action
SecureStack C2 Configuration Guide 7-27
Defaults
None.
Mode
Switchmode,readwrite.
Example
Thisexampleshowshowtosetthelinkflapviolationactiononportge.1.4togeneratingaSyslog
entry.
C2(rw)->set linkflap action ge.1.4 gensyslogentry
clear linkflap action
Usethiscommandtoclearreactionstoalinkflapviolation.
Syntax
clear linkflap action [port-string] {disableInterface | gensyslogentry | gentrap
| all}
Parameters
Defaults
Ifportstringisnotspecified,actionswillbeclearedonallports.
Mode
Switchmode,readwrite.
Example
Thisexampleshowshowtoclearthelinkflapviolationactiononportge.1.4togeneratinga
Syslogentry.
C2(rw)->clear linkflap action ge.1.4 gensyslogentry
set linkflap threshold
Usethiscommandtosetthelinkflapactiontriggercount.
Syntax
set linkflap threshold port-string threshold-value
portstring (Optional)Specifiestheport(s)onwhichtoclearthelinkflapaction.
disableInterface Clearsthereactionasdisablingtheinterface.
gensyslogentry Clearsthe reactionasgeneratingasyslogentry.
gentrap ClearsthereactionasgeneratinganSNMPtrap.
all Clearsthereactionasalloftheabove.